Trapped key interlocking utilizes locks and keys for sequential control of equipment and machinery to ensure safe operation. Trapped key interlocks are widely used to ensure safe access to potentially live or dangerous plant or equipment in an industrial setting.

This is a trapped key interlock on the door of an electrical switchgear cabinet. It is attached with one-way security screws to discourage casual removal, which would defeat the interlock scheme.

Trapped key interlocking utilizes locks and keys for sequential control of equipment and machinery to ensure safe operation. Trapped key interlocks are widely used to ensure safe access to potentially live or dangerous plant or equipment in an industrial setting.

Kirk Key Generator Connection Boxes

  • For business owners, nothing is more frustrating than losing power in your store, office, or commercial property. Without it, many critical duties and responsibilities are delayed or lost entirely—your heating and cooling system, electrical system, security system, computer networks (including individual workstations, servers, printers, etc.), and your building’s tankless water heater are.
  • ESL's Manual Transfer Switch provides an economical and safe solution for grid-tied facilities to quickly and easily connect a portable generator. ESL's Manual Transfer Switch provides an economical and safe solution for grid-tied facilities to quickly and easily connect a portable generator. No KIRK® key. or trapped key interlocks are.
  • Easily connect a portable energy source to any building, hospital, pump station or concert hall using our line of generator docking stations. Built to the current NEC and UL standards and with the installing electrical contractor in mind, we manufacture a full line of products to safely connect a portable generator and/or load bank that help protect you, your business and your customers from.
  • Using KIRK® interlocks when connecting ship’s power cables to on shore power will ensure that the cables are properly coupled to the junction box before energizing.
  • 2-Key Interlock Provision. Prevents access to temporary connections unless key is present. Key is held captive when door is open. Note that this is a provision only for user-provided key interlock. See downloads for additional details. Downloads: Key Interlock Instructions Kirk SD Series Type D Data Sheet.
  • Trapped key interlocks have a number of functions in substation switchgear applications. For example, preventing the paralleling of two energy sources, preventing particular operations until a breaker is locked open or closed, preventing disconnecting of breakers under load, and minimizing the possibility of a hazardous arc flash.

A safe sequence of operations is enabled through transfer of keys that are either trapped or released in a predetermined order. For example, a key is used to isolate a power source (circuit breaker or supply valve), this key is then released and can then be used to gain access through a gate or door to a high risk area by inserting it into an access lock. The key will then remain trapped until the gate or door is closed. A personnel or safety key can be released from the access lock, this ensures that the gate or door can not be closed and the initial key released until this personnel or safety key is returned. This provides increased operator safety.

Trapped key interlocks were used in the French railway system in the 1890s to control track switching operations. French inventor was Mr Bourré. His original company is now known as STI, Serv Trayvou Interverrouillage SA[1]. Later on, the Englishman James Harry Castell[2] (1880-1953), Frenchman, B. Trayvou[3] and the American R. L. Kirk [4] developed trapped key interlocking systems, and such systems are often referred to as Castell or Bourre Keys or Trayvou keys or Kirk key interlock systems. Both worked in the power generation and distribution industries in the early part of the 20th century, and both pioneered the use of trapped key interlock for switchgear control. Trapped key interlocks can be found in many industrial settings including electrical utilities, railway, petroleum, and chemical plants as a response to occupational safety and health legislation.

Kirk Key Generator Connection Box

Interlock devices[edit]

A typical trapped-key interlock device consists of a lock cylinder which operates a sliding bolt through a cam. The assembly is contained in a housing, which is made in different styles to accommodate different applications. The sliding bolt, when extended, mechanically prevents operation of a switch, valve, gate, or other device. Many variations exist, with different shapes of interlock bolt and multiple lock cylinders on an interlock. A significant feature of the interlock is that the key is held or trapped in one position of the lock. Releasing the key indicates that the interlocked device has been made safe; the interlocked device cannot be re-energized until the key has been returned and operated to retract the bolt.

Kirk Key Generator Connection Box For Sale

Some complex sequences use key exchange blocks or boxes, that allow alternative sequences of operation.Interlock devices may have an electrical solenoid which holds the key until an electrical circuit is interrupted; for example, the power supply for a high-voltage cabinet has been de-energized, releasing a key to allow access to the interior of the cabinet. Some interlocks include a time delay function or a rotation detector to ensure a machine has had time to come to a stop before allowing the next step of an interlock sequence to proceed.[5] A key exchange block may only hold and release keys and may not have a bolt to interlock process equipment, or may be part of the interlock of a particular machine or device.

This is a transfer block, part of a trapped key interlock system. It does not have a bolt to stop operation of a device, but holds and releases other keys.

Manufacturers of trapped key interlock devices provide application guides showing typical interlock problems and recommended arrangements. Since the reliability and safety of the scheme critically depends on the possession of keys, duplicate keys must be carefully controlled to prevent any possibility of an unsafe operating sequence. /steam-generating-a-beta-key.html. For example, a lost key might be replaced only by a duplicate held off-site, or might require ordering a replacement from the original manufacturer.

Kirk Key Generator Connection Box For Free

Example[edit]

For example, to prevent access to the inside of an electric kiln while it is operating, a trapped key system may be used to interlock a disconnecting switch and the kiln door. Whenever the kiln power switch is turned on, the key is automatically held by the interlock, and cannot be manually removed. In order to open the kiln door, the power switch must first be turned off, which releases the key and allows it to be removed from the interlock. The key can then be used to unlock the kiln door. While the key is removed from the switch interlock, a plunger from the interlock mechanically prevents the power switch from being turned on. Power cannot be re-applied to the kiln until the kiln door is locked, releasing the key, and the key is then returned to the power switch interlock.[6] A similar two-part interlock system can be used anywhere it is necessary to ensure the energy supply to a machine is interrupted before the machine is entered for adjustment or maintenance.

See also[edit]

Kirk Key Generator Connection Box Diagram

References[edit]

Generator Connection

  1. ^S.T.I.
  2. ^Castell
  3. ^S.T.I.
  4. ^'Kirk'. KirkKey.com.
  5. ^Macdonald, David (2004). Practical Machinery Safety. Newnes. p. 152. ISBN0750662700.
  6. ^Harry Fraser, The electric kiln: a user's manual 2nd edition, University of Pennsylvania Press, 2000, page 41
Generator connection box

Kirk Key Generator Connection Box On Pole

Retrieved from 'https://en.wikipedia.org/w/index.php?title=Trapped_key_interlocking&oldid=858319403'